Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
EClinicalMedicine ; 72: 102600, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38633574

RESUMO

Background: Fetal growth restriction (FGR) can negatively affect lung development, leading to increased respiratory morbidity and reduced lung function later in life. Studies regarding the impact of FGR on lung function in singletons are influenced by genetic, obstetric, and maternal factors. To overcome these confounding factors, we aim to investigate lung function in identical twins with selective FGR (sFGR). Methods: Lung function assessments were performed in identical twins with sFGR born in our centre between March 1, 2002, and December 31, 2017, aged between 5 and 17 years. sFGR was defined as birthweight discordance ≥20%. Outcome measures consisted of forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), and transfer factor for carbon monoxide (DLCO) and were compared between the smaller and larger twin. Findings: Thirty-nine twin pairs performed spirometry of sufficient quality. Median gestational age at birth was 34.3 (interquartile range (IQR) 32.1-36.0) weeks with median birthweights of 1500 (IQR 1160-1880) grams and 2178 (IQR 1675-2720) grams for the smaller and larger twin, respectively. Smaller twins had significantly lower z-scores for FEV1 (-0.94 versus -0.41, p = 0.0015), FVC (-0.56 versus -0.06, p < 0.0001) and DLCO (-0.50 versus 0.00, p < 0.0001) compared to larger co-twins. Interpretation: Although being genetically identical, sFGR in identical twins is associated with a reduction in static and dynamic lung volume and a reduction in lung diffusion, even when taking the reduced lung volume into account. This indicates that adverse growth conditions in utero negatively affect lung development and function, potentially contributing to an increase in respiratory morbidities later in life. Funding: The Dutch Heart Foundation and The Bontius Foundation.

2.
Prenat Diagn ; 2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38643403

RESUMO

OBJECTIVES: This systematic review explores cardiac adaptation in monochorionic (MC) twins with twin-twin transfusion syndrome (TTTS) or selective fetal growth restriction (sFGR) and assesses the risk of congenital heart defects (CHDs). METHODS: Adhering to PRISMA guidelines, 63 studies were reviewed (49 on cardiac adaptation, 13 on CHD, one on both). A narrative synthesis of cardiac adaptation patterns was performed. Additionally, a meta-analysis compared the livebirth prevalence of CHD in TTTS and sFGR against uncomplicated MC twins. RESULTS: In TTTS recipients, cardiac function may be impaired for diastolic, systolic, as well as global functions, while in donors, cardiac function is generally preserved. In sFGR, large twins may show hypertrophic cardiomyopathy, and small twins may show impaired systolic function. Co-occurrence of TTTS and sFGR magnifies cardiac impact but is often underreported. Meta-analysis for CHD prevalence revealed a relative risk ratio of 3.5 (95% CI: 2.5-4.9) for TTTS and 2.2 (95%CI: 1.3-3.5) for sFGR compared with uncomplicated MC twins. CONCLUSIONS: This study highlights the well-documented cardiac adaptation in TTTS, contrasting with limited understanding in sFGR. Elevated CHD risks were observed in both conditions. Enhanced cardiovascular surveillance is warranted in complicated MC twin pregnancies. Future research should explore cardiac adaptation in sFGR and its long-term consequences.

3.
Med Image Anal ; 94: 103147, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38547665

RESUMO

Three-dimensional (3D) ultrasound imaging has contributed to our understanding of fetal developmental processes by providing rich contextual information of the inherently 3D anatomies. However, its use is limited in clinical settings, due to the high purchasing costs and limited diagnostic practicality. Freehand 2D ultrasound imaging, in contrast, is routinely used in standard obstetric exams, but inherently lacks a 3D representation of the anatomies, which limits its potential for more advanced assessment. Such full representations are challenging to recover even with external tracking devices due to internal fetal movement which is independent from the operator-led trajectory of the probe. Capitalizing on the flexibility offered by freehand 2D ultrasound acquisition, we propose ImplicitVol to reconstruct 3D volumes from non-sensor-tracked 2D ultrasound sweeps. Conventionally, reconstructions are performed on a discrete voxel grid. We, however, employ a deep neural network to represent, for the first time, the reconstructed volume as an implicit function. Specifically, ImplicitVol takes a set of 2D images as input, predicts their locations in 3D space, jointly refines the inferred locations, and learns a full volumetric reconstruction. When testing natively-acquired and volume-sampled 2D ultrasound video sequences collected from different manufacturers, the 3D volumes reconstructed by ImplicitVol show significantly better visual and semantic quality than the existing interpolation-based reconstruction approaches. The inherent continuity of implicit representation also enables ImplicitVol to reconstruct the volume to arbitrarily high resolutions. As formulated, ImplicitVol has the potential to integrate seamlessly into the clinical workflow, while providing richer information for diagnosis and evaluation of the developing brain.


Assuntos
Algoritmos , Imageamento Tridimensional , Humanos , Feminino , Gravidez , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Ultrassonografia Pré-Natal , Encéfalo/diagnóstico por imagem
4.
Prenat Diagn ; 44(3): 289-296, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38342960

RESUMO

OBJECTIVE: To evaluate which cytogenetic characteristics of confined placental mosaicism (CPM) detected in the first trimester chorionic villi and/or placentas in terms of chromosome aberration, cell lineage involved and trisomy origin will lead to fetal growth restriction and low birthweight. METHODS: Cohort study using routinely collected perinatal data and cytogenetic data of non-invasive prenatal testing, the first trimester chorionic villi sampling and postnatal placentas. RESULTS: 215 CPM cases were found. Fetal growth restriction (FGR) and low birthweight below the 10th percentile (BW < p10) were seen in 34.0% and 23.1%, respectively. Excluding cases of trisomy 16, 29.1% showed FGR and 17.9% had a BW < p10. The highest rate of FGR and BW < p10 was found in CPM type 3, but differences with type 1 and 2 were not significant. FGR and BW < p10 were significantly more often observed in cases with meiotic trisomies. CONCLUSION: There is an association between CPM and FGR and BW < p10. This association is not restricted to trisomy 16, neither to CPM type 3, nor to CPM involving a meiotic trisomy. Pregnancies with all CPM types and origins should be considered to be at increased risk of FGR and low BW < p10. A close prenatal fetal monitoring is indicated in all cases of CPM.


Assuntos
Placenta , Trissomia , Gravidez , Feminino , Humanos , Placenta/metabolismo , Trissomia/diagnóstico , Trissomia/genética , Mosaicismo , Retardo do Crescimento Fetal/diagnóstico , Retardo do Crescimento Fetal/genética , Estudos de Coortes , Peso ao Nascer , Estudos Retrospectivos , Cromossomos Humanos Par 16
5.
Eur J Obstet Gynecol Reprod Biol X ; 21: 100289, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38384382

RESUMO

Objective: Ultrasonographic examination is the first-tier test to detect abnormal development of central nervous system (CNS). In optimal conditions, neurosonography can detect all important hallmarks of CNS development. It is, however, not known how the performance of this modality is in a routine setting. We aimed to evaluate the feasibility of neurosonography in a time-limited routine setting. Study design: We have performed a prospective study in which we have included a group of pregnant women carrying a fetus with an isolated congenital heart defect (CHD), and a control group of fetuses without structural anomalies. We have performed basic neurosonography examination according to the guideline 'how to perform a basic screening examination of the CNS', published by the international society of ultrasound in obstetrics and gynecology in both groups. In all these examinations, 9 brain structures were scored in 3 different planes, by researchers that were blinded for group allocation. A sufficient neurosonogram was performed when 7 or more out of 9 CNS structures were clearly visible during the off-line scoring of the examination. Results: A total of 574 neurosonographic examinations were performed in 151 fetuses, 90 in the CHD-group and 61 in the control group. A sufficient neurosonogram could be performed in 79% (234/294) of cases in a clinical setting (CHD cases) and in 90% (253/280) of control pregnancies. Higher maternal BMI (>30), maternal age, fetal cephalic position, fetal gender and placental position did not significantly influence neurosonography scores. Conclusion: In clinical setting, basic fetal neurosonography can be sufficiently performed in the majority of cases. This was not significantly influenced by maternal or fetal factors. The optimal gestational age for neurosonography is between 22 and 34 weeks.

6.
J Med Genet ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38272662

RESUMO

Fetal hydrops as detected by prenatal ultrasound usually carries a poor prognosis depending on the underlying aetiology. We describe the prenatal and postnatal clinical course of two unrelated female probands in whom de novo heterozygous missense variants in the planar cell polarity gene CELSR1 were detected using exome sequencing. Using several in vitro assays, we show that the CELSR1 p.(Cys1318Tyr) variant disrupted the subcellular localisation, affected cell-cell junction, impaired planar cell polarity signalling and lowered proliferation rate. These observations suggest that deleterious rare CELSR1 variants could be a possible cause of fetal hydrops.

7.
Catheter Cardiovasc Interv ; 103(2): 308-316, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38091308

RESUMO

BACKGROUND: Balloon atrial septostomy (BAS) is an emergent and essential cardiac intervention to enhance intercirculatory mixing at atrial level in deoxygenated patients diagnosed with transposition of the great arteries (TGA) and restrictive foramen ovale. The recent recall of several BAS catheters and the changes in the European legal framework for medical devices (MDR 2017/745), has led to an overall scarcity of BAS catheters and raised questions about the use, safety, and experience of the remaining NuMED Z-5 BAS catheter. AIMS: To evaluate and describe the practice and safety of the Z-5 BAS catheter, and to compare it to the performance of other BAS catheters. METHODS: A retrospective single-center cohort encompassing all BAS procedures performed with the Z-5 BAS catheter in TGA patients between 1999 and 2022. RESULTS: A total of 182 BAS procedures were performed in 179 TGA-newborns at Day 1 (IQR 0-5) days after birth, with median weight of 3.4 (IQR 1.2-5.7) kg. The need for BAS was urgent in 90% of patients. The percentage of BAS procedures performed at bedside increased over time from 9.8% (before 2010) to 67% (2017-2022). Major complication rate was 2.2%, consisting of cerebral infarction (1.6%) and hypovolemic shock (0.5%). The rate of minor complications was 9.3%, including temporary periprocedural AV-block (3.8%), femoral vein thrombosis (2.7%), transient intracardiac thrombus (0.5%), and atrial flutter (2.2%). BAS procedures performed at bedside and in the cardiac catheterization laboratory had similar complication rates. CONCLUSIONS: BAS using the Z-5 BAS catheter is both feasible and safe at bedside and at the cardiac catheterization laboratory with minimal major complications.


Assuntos
Transposição dos Grandes Vasos , Humanos , Recém-Nascido , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Transposição dos Grandes Vasos/complicações , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Artérias
8.
Prenat Diagn ; 43(12): 1495-1505, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37964422

RESUMO

Several factors associated with poor outcome in patients with prenatally diagnosed sacrococcygeal teratoma (SCT) have been found. However, the prognostic accuracy of these factors has not been well established. Therefore, we aimed to systematically review the prognostic accuracy of factors associated with poor outcome in these patients. We queried Search Premier, COCHRANE Library, EMCARE, EMBASE, PubMed, ScienceDirect, and Web of Science databases to identify studies regarding patients with prenatally diagnosed SCT. Poor outcome was defined as termination of pregnancy (TOP), intrauterine fetal death (IUFD), or perinatal death. We estimated the odds ratio of factors associated with poor outcome. Eleven studies (447 patients) were included. Overall mortality, including TOP, was 34.9%. Factors associated with poor outcome in fetuses with prenatally diagnosed SCT were cardiomegaly, hypervascular tumor, solid tumor morphology, fetal hydrops, and placentomegaly. A tumor volume to fetal weight ratio (TFR) of >0.12 before a gestational age of 24 weeks is predictive of poor outcome. The prognostic accuracy of factors associated with poor outcome in fetuses prenatally diagnosed with SCT seems promising. Factors associated with cardiac failure such as cardiomegaly, hypervascular tumor, solid tumor morphology, fetal hydrops, placentomegaly, and TFR >0.12 were found to be predictive of poor outcome.


Assuntos
Hidropisia Fetal , Teratoma , Gravidez , Feminino , Humanos , Lactente , Prognóstico , Hidropisia Fetal/patologia , Ultrassonografia Pré-Natal , Teratoma/diagnóstico por imagem , Teratoma/complicações , Cardiomegalia/complicações , Cardiomegalia/patologia , Região Sacrococcígea/diagnóstico por imagem
9.
BMC Pregnancy Childbirth ; 23(1): 694, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37752446

RESUMO

BACKGROUND: Since 2007 all pregnant women in the Netherlands are offered the second-trimester anomaly scan (SAS) in a nationwide prenatal screening program. This study aims to assess the level of informed choice of women opting for the SAS and to evaluate the presence of routinization 16 years after its implementation. It further explores decisional conflict and women's decision making. METHODS: This prospective national survey study consisted of an online questionnaire which was completed after prenatal counseling and before undergoing the SAS. Informed choice was measured by the adapted multidimensional measure of informed choice (MMIC) and was defined in case women were classified as value-consistent, if their decision for the SAS was deliberated and made with sufficient knowledge. RESULTS: A total of 894/1167 (76.6%) women completed the questionnaire. Overall, 54.8% made an informed choice, 89.6% had good knowledge, 59.8% had deliberated their choice and 92.7% held a positive attitude towards the SAS. Women with low educational attainment (p=0.004) or respondents of non-Western descent (p=0.038) were less likely to make an informed choice. Decisional conflict was low, with a significantly lower decisional conflict score in women that made an informed choice (p<0.001). Most respondents (97.9%) did not perceive pressure to undergo the SAS. CONCLUSIONS: Our study showed a relatively low rate of informed choice for the SAS, due to absence of deliberation. Therefore, some routinization seem to be present in the Netherlands. However, most women had sufficient knowledge, did not perceive pressure and experienced low decisional conflict.


Assuntos
Estudos de Coortes , Gravidez , Feminino , Humanos , Masculino , Países Baixos , Estudos Prospectivos , Segundo Trimestre da Gravidez , Escolaridade
10.
Eur J Endocrinol ; 189(2): 183-189, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37548178

RESUMO

OBJECTIVE: Research suggests that postnatal catch-up growth after fetal growth restriction (FGR) occurs frequently. Yet, postnatal growth in singletons may be influenced by multiple factors. Identical twins with discordant prenatal growth, termed selective FGR (sFGR), can be regarded as a natural experiment eliminating these sources of bias. DESIGN: Observational cohort study. METHODS: Monochorionic twins with sFGR born between 2002 and 2017 (aged 3-17 years) were eligible. Growth measurements (height, weight, head circumference, and body mass index) were performed at follow-up. Detailed growth curves documented by a systematic primary care system in the Netherlands were collected. Measurements were converted to standard deviation scores (SDSs). A mixed-effects model was used to assess within-pair SDS difference and individual height SDS relative to target height SDS. RESULTS: Forty-seven twin pairs (94 children) were included at a median age of 11 (interquartile range 8-13) years. At the last measurement, smaller twins at birth had a lower height SDS [-0.6 vs -0.3, P < .001, median difference 0.5 (95%CI 0.4-0.7)], lower weight SDS [-0.5 vs -0.1, P < .001, median difference 0.8 (95%CI 0.5-1.0)], and lower head circumference SDS [-0.5 vs 0.2, P < .001, median difference 0.8 (95%CI 0.6-0.9)] compared to larger twins. These differences persisted until the age of 17. Smaller twins showed rapid catch-up growth in the first 2 years and reached their target height range between 8 and 11 years. CONCLUSIONS: Identical twins with discordant prenatal growth maintain a modest but significant difference in height, weight, and head circumference, indicating a persistent, inhibitory effect of an adverse intrauterine environment on childhood growth.


Assuntos
Retardo do Crescimento Fetal , Gêmeos Monozigóticos , Gravidez , Recém-Nascido , Feminino , Criança , Humanos , Adolescente , Índice de Massa Corporal , Estudos de Coortes , Estatura , Peso ao Nascer
12.
Cytotherapy ; 25(10): 1057-1068, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37516948

RESUMO

BACKGROUND AIMS: Human umbilical cord-derived mesenchymal stromal cells (hUC-MSCs) are increasingly used in research and therapy. To obtain hUC-MSCs, a diversity of isolation and expansion methods are applied. Here, we report on a robust and standardized method for hUC-MSC isolation and expansion. METHODS: Using 90 hUC donors, we compared and optimized critical variables during each phase of the multi-step procedure involving UC collection, processing, MSC isolation, expansion and characterization. Furthermore, we assessed the effect of donor-to-donor variability regarding UC morphology and donor attributes on hUC-MSC characteristics. RESULTS: We demonstrated robustness of our method across 90 UC donors at each step of the procedure. With our method, UCs can be collected up to 6 h after birth, and UC-processing can be initiated up to 48 h after collection without impacting on hUC-MSC characteristics. The removal of blood vessels before explant cultures improved hUC-MSC purity. Expansion in Minimum essential medium α supplemented with human platelet lysate increased reproducibility of the expansion rate and MSC characteristics as compared with Dulbecco's Modified Eagle's Medium supplemented with fetal bovine serum. The isolated hUC-MSCs showed a purity of ∼98.9%, a viability of >97% and a high proliferative capacity. Trilineage differentiation capacity of hUC-MSCs was reduced as compared with bone marrow-derived MSCs. Functional assays indicated that the hUC-MSCs were able to inhibit T-cell proliferation demonstrating their immune-modulatory capacity. CONCLUSIONS: We present a robust and standardized method to isolate and expand hUC-MSCs, minimizing technical variability and thereby lay a foundation to advance reliability and comparability of results obtained from different donors and different studies.


Assuntos
Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Humanos , Reprodutibilidade dos Testes , Cordão Umbilical , Diferenciação Celular , Proliferação de Células
13.
Fetal Diagn Ther ; 50(4): 289-298, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37285826

RESUMO

INTRODUCTION: Perforation of the intertwin membrane can occur as a complication of fetoscopic laser surgery for twin-twin transfusion syndrome (TTTS). Data on the occurrence and the risk of subsequent cord entanglement are limited. The objective of this study was to assess the prevalence, risk factors and outcome of intertwin membrane perforation, and cord entanglement after laser surgery for TTTS. METHODS: In this multicenter retrospective study, we included all TTTS pregnancies treated with laser surgery in two fetal therapy centers, Shanghai (China) and Leiden (the Netherlands) between 2002 and 2020. We evaluated the occurrence of intertwin membrane perforation and cord entanglement after laser, based on routine fortnightly ultrasound examination and investigated the risk factors and the association with adverse short- and long-term outcomes. RESULTS: Perforation of the intertwin membrane occurred in 118 (16%) of the 761 TTTS pregnancies treated with laser surgery and was followed by cord entanglement in 21% (25/118). Perforation of the intertwin membrane was associated with higher laser power settings, 45.8 Watt versus 42.2 Watt (p = 0.029) and a second fetal surgery procedure 17% versus 6% (p < 0.001). The group with intertwin membrane perforation had a higher rate of caesarean section (77% vs. 31%, p < 0.001) and a lower gestational age at birth (30.7 vs. 33.3 weeks of gestation, p < 0.001) compared to the group with an intact intertwin membrane. Severe cerebral injury occurred more often in the group with intertwin membrane perforation, 9% (17/185) versus 5% (42/930), respectively (p = 0.019). Neurodevelopmental outcome at 2 years of age was similar between the groups with and without perforation of the intertwin membrane and between the subgroups with and without cord entanglement. CONCLUSION: Perforation of the intertwin membrane after laser occurred in 16% of TTTS cases treated with laser and led to cord entanglement in at least 1 in 5 cases. Intertwin membrane perforation was associated with a lower gestational age at birth and a higher rate of severe cerebral injury in surviving neonates.


Assuntos
Transfusão Feto-Fetal , Terapia a Laser , Recém-Nascido , Gravidez , Humanos , Feminino , Transfusão Feto-Fetal/cirurgia , Estudos Retrospectivos , Prevalência , Cesárea , China , Terapia a Laser/efeitos adversos , Terapia a Laser/métodos , Fetoscopia/efeitos adversos , Fetoscopia/métodos , Fatores de Risco , Cordão Umbilical/diagnóstico por imagem , Cordão Umbilical/cirurgia , Idade Gestacional , Gravidez de Gêmeos
14.
Prenat Diagn ; 43(7): 873-880, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37269059

RESUMO

OBJECTIVES: First-trimester ultrasound screening is increasingly performed to detect fetal anomalies early in pregnancy, aiming to enhance reproductive autonomy for future parents. This study aims to display the current practice of first-trimester ultrasound screening in developed countries. METHOD: An online survey among 47 prenatal screening experts in developed countries. RESULTS: First-trimester structural anomaly screening is available in 30 of the 33 countries and is mostly offered to all women with generally high uptakes. National protocols are available in 23/30 (76.7%) countries, but the extent of anatomy assessment varies. Monitoring of scan quality occurs in 43.3% of the countries. 23/43 (53.5%) of the respondents considered the quality of first-trimester ultrasound screening unequal in different regions of their country. CONCLUSIONS: First-trimester screening for structural fetal anomalies is widely offered in developed countries, but large differences are reported in availability and use of screening protocols, the extent of anatomy assessment, training and experience of sonographers and quality monitoring systems. Consequently, this results in an unequal offer to parents in developed countries, sometimes even within the same country. Furthermore, as offer and execution differ widely, this has to be taken into account when results of screening policies are scientifically published or compared.


Assuntos
Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal , Gravidez , Humanos , Feminino , Primeiro Trimestre da Gravidez , Países Desenvolvidos , Diagnóstico Pré-Natal/métodos , Ultrassonografia
15.
Fetal Diagn Ther ; 50(4): 248-258, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37331329

RESUMO

INTRODUCTION: Early detection of isolated severe congenital heart defects (CHDs) allows extra time for chromosomal analysis and informed decision making, resulting in improved perinatal management and patient satisfaction. Therefore, the aim of this study was to assess the value of an additional first-trimester screening scan compared to only a second-trimester scan in fetuses diagnosed with isolated severe CHDs. Prenatal detection rate, time of prenatal diagnosis, and pregnancy outcome were evaluated in the Netherlands after implementation of a national screening program. MATERIALS AND METHODS: We performed a retrospective geographical cohort study and included 264 pre- and postnatally diagnosed isolated severe CHD cases between January 1, 2007, and December 31, 2015, in the Amsterdam region. Severe CHD was defined as potentially life threatening if intervention within the first year of life was required. Two groups were defined: those with a first- and second-trimester anomaly scan (group 1) and those with a second-trimester anomaly scan only (group 2). A first-trimester scan was defined as a scan between 11 + 0 and 13 + 6 weeks of gestation. RESULTS: Overall, the prenatal detection rate for isolated severe CHDs was 65%; 63% were detected before 24 weeks of gestation (97% of all prenatally detected CHDs). Prenatal detection rate was 70.2% in the group with a first- and second-trimester scan (group 1) and 58% in the group with a second-trimester scan only (group 2) (p < 0.05). Median gestational age at detection was 19 + 6 (interquartile range [IQR] 15 + 4 - 20 + 5) in group 1 versus 20 + 3 (IQR: 20 + 0 - 21 + 1) in group 2 (p < 0.001). In group 1, 22% were diagnosed before 18 weeks of gestation. Termination of pregnancy rate in group 1 and group 2 were 48% and 27%, respectively (p < 0.01). Median gestational age at termination did not differ between the two groups. CONCLUSION: Prenatal detection rate of isolated severe CHDs and termination of pregnancy rate was higher in the group with both a first- and second-trimester scan. We found no differences between timing of terminations. The additional time after diagnosis allows for additional genetic testing and optimal counseling of expectant parents regarding prognosis and perinatal management, so that well-informed decisions can be made.


Assuntos
Cardiopatias Congênitas , Feminino , Gravidez , Humanos , Estudos de Coortes , Estudos Retrospectivos , Cardiopatias Congênitas/diagnóstico por imagem , Diagnóstico Pré-Natal , Resultado da Gravidez , Ultrassonografia Pré-Natal/métodos
16.
Am J Obstet Gynecol MFM ; 5(8): 101023, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37220848

RESUMO

BACKGROUND: Congenital heart defects are the most common congenital anomaly. Despite the increasing survival of these children, there is still an increased incidence of fetal demise, frequently attributed to cardiac failure. Considering that abnormal placental development has been described in congenital heart disease, our hypothesis is that placental insufficiency may contribute to fetal death in congenital heart disease. OBJECTIVE: This study aimed to assess cases with fetal congenital heart disease and intrauterine demise, and analyze factors that are related to the demise. STUDY DESIGN: All congenital heart disease cases diagnosed prenatally during the period January 2002 to January 2021 were selected from the regional prospective congenital heart disease registry, PRECOR. Multiple pregnancies and pregnancies with fetal trisomy 13 or 18, triploidy, and Turner's syndrome were excluded from the analysis, because fetal demise is attributed to the chromosomal abnormality in these cases. Cases were categorized into 4 groups based on the possible cause of fetal death as follows: cardiac failure, additional (genetic) diagnosis, placental insufficiency, and a group in which no cause was found. A separate analysis was performed for isolated congenital heart disease cases. RESULTS: Of the 4806 cases in the PRECOR registry, 112 had fetal demise, of which 43 were excluded from the analysis (13 multiple pregnancies, 30 genetic). Of these, 47.8% were most likely related to cardiac failure, 42.0% to another (genetic) diagnosis, and 10.1% to placental insufficiency. No cases were allocated to the group with an unknown cause. Only 47.8% of the cases had isolated congenital heart disease, and in this group 21.2% was most likely related to placental insufficiency. CONCLUSION: This study shows that in addition to cardiac failure and other (genetic) diagnoses, placental factors play an important role in fetal demise in congenital heart disease, especially in cases of isolated heart defects. Therefore, these findings support the importance of regular ultrasonographic assessment of fetal growth and placental function in fetal congenital heart disease.


Assuntos
Doenças Fetais , Cardiopatias Congênitas , Insuficiência Cardíaca , Insuficiência Placentária , Criança , Gravidez , Feminino , Humanos , Insuficiência Placentária/epidemiologia , Placenta , Estudos Prospectivos , Morte Fetal/etiologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/epidemiologia
17.
Prenat Diagn ; 43(5): 629-638, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36738444

RESUMO

OBJECTIVES: To determine the proportion of children that require surgery in the first year of life and thereafter in order to improve the counseling of parents with a fetus with a right aortic arch (RAA). METHODS: Fetuses diagnosed with isolated RAA, defined as the absence of intra- or extracardiac anomalies, between 2007 and 2021 were extracted from the prospective registry PRECOR. RESULTS: In total, 110 fetuses were included, 92 with a prenatal diagnosis of RAA and 18 with double aortic arch (DAA). The prevalence of 22q11 deletion syndrome was 5.5%. Six pregnancies were terminated and five cases were false-positive; therefore, the follow-up consisted of 99 neonates. Surgery was performed in 10 infants (10%) in the first year of life. In total, 25 (25%) children had surgery at a mean age of 17 months. Eight of these 25 (32%) had a DAA. Only one child, with a DAA, required surgery in the first week of life due to obstructive stridor. CONCLUSIONS: Children with a prenatally diagnosed RAA are at a low risk of acute respiratory postnatal problems. Delivery in a hospital with neonatal intensive care and pediatric cardiothoracic facilities seems only indicated in cases with suspected DAA. Expectant parents should be informed that presently 25% of the children need elective surgery and only incidentally due to acute respiratory distress.


Assuntos
Síndromes do Arco Aórtico , Anel Vascular , Gravidez , Lactente , Recém-Nascido , Feminino , Humanos , Criança , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ultrassonografia Pré-Natal , Estudos Retrospectivos , Diagnóstico Pré-Natal , Síndromes do Arco Aórtico/diagnóstico por imagem , Síndromes do Arco Aórtico/cirurgia
18.
Prenat Diagn ; 43(5): 639-646, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36811197

RESUMO

OBJECTIVE: Congenital heart disease (CHD) is associated with decreased birthweight (BW) compared to population-based references. The aim of this study was to compare the BW of isolated CHD cases to their siblings, thus controlling for unknown and unmeasured confounders within the family. METHODS: All isolated CHD cases in the Leiden University Medical Center were included (2002-2019). Generalized estimated equation models were constructed to compare BW z scores of CHD neonates with their siblings. Cases were clustered to minor or severe CHD and stratified according to the aortic flow and oxygenation to the brain. RESULTS: The overall BW z score of siblings was 0.032 (n = 471). The BW z score was significantly lower in CHD cases (n = 291) compared to their siblings (-0.20, p = 0.005). The results were consistent in the subgroup analysis of severe and minor CHD (BW z score difference -0.20 and -0.10), but did not differ significantly (p = 0.63). Stratified analysis regarding flow and oxygenation showed no BW difference between the groups (p = 0.1). CONCLUSION: Isolated CHD cases display a significantly lower BW z score compared to their siblings. As the siblings of these CHD cases show a BW distribution similar to the general population, this suggests that shared environmental and maternal influences between siblings do not explain the difference in BW.


Assuntos
Cardiopatias Congênitas , Irmãos , Recém-Nascido , Humanos , Criança , Peso ao Nascer , Cardiopatias Congênitas/epidemiologia , Encéfalo , Cabeça
19.
Prenat Diagn ; 43(5): 620-628, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36549919

RESUMO

OBJECTIVE: We aimed to assess current prenatal detection rate (DR) of aortic coarctation (CoA) and its impact on neonatal outcome in the Netherlands to evaluate the efficacy of the Dutch screening protocol in which the cardiac four-chamber view, outflow tracts and three-vessel view are compulsory. METHODS: All prenatally and postnatally diagnosed CoA cases between 2012 and 2021 were extracted from our PRECOR-registry. Annual DRs were calculated with a focus on the trend over time and attributing factors for detection. Postnatal outcome was compared between prenatally detected and undetected cases. RESULTS: 49/116 cases (42.2%) were detected prenatally. A higher chance of detection was found for cases with extracardiac malformations (71.4%; p = 0.001) and the more severe cases with an aortic arch hypoplasia and/or ventricular septal defect (63.2%; p = 0.001). Time-trend analysis showed no improvement in DR over time (p = 0.33). Undetected cases presented with acute circulatory shock in 20.9% and were more likely to have severe lactic acidosis (p = 0.02) and impaired cardiac function (p < 0.001) before surgery. CONCLUSION: Even in a well-organized screening program, the DR of CoA still requires improvement, especially in isolated cases. The increased risk of severe lactic acidosis in undetected cases stresses the need for urgent additions to the current screening program, such as implementation of the three-vessel trachea view and measurement of outflow tracts.


Assuntos
Acidose Láctica , Coartação Aórtica , Comunicação Interventricular , Gravidez , Recém-Nascido , Feminino , Humanos , Coartação Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Países Baixos/epidemiologia , Ultrassonografia Pré-Natal/métodos , Estudos Retrospectivos
20.
Eur J Hum Genet ; 31(1): 97-104, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36253531

RESUMO

Autosomal dominant variants in LDB3 (also known as ZASP), encoding the PDZ-LIM domain-binding factor, have been linked to a late onset phenotype of cardiomyopathy and myofibrillar myopathy in humans. However, despite knockout mice displaying a much more severe phenotype with premature death, bi-allelic variants in LDB3 have not yet been reported. Here we identify biallelic loss-of-function variants in five unrelated cardiomyopathy families by next-generation sequencing. In the first family, we identified compound heterozygous LOF variants in LDB3 in a fetus with bilateral talipes and mild left cardiac ventricular enlargement. Ultra-structural examination revealed highly irregular Z-disc formation, and RNA analysis demonstrated little/no expression of LDB3 protein with a functional C-terminal LIM domain in muscle tissue from the affected fetus. In a second family, a homozygous LDB3 nonsense variant was identified in a young girl with severe early-onset dilated cardiomyopathy with left ventricular non-compaction; the same homozygous nonsense variant was identified in a third unrelated female infant with dilated cardiomyopathy. We further identified homozygous LDB3 frameshift variants in two unrelated probands diagnosed with cardiomegaly and severely reduced left ventricular ejection fraction. Our findings demonstrate that recessive LDB3 variants can lead to an early-onset severe human phenotype of cardiomyopathy and myopathy, reminiscent of the knockout mouse phenotype, and supporting a loss of function mechanism.


Assuntos
Cardiomiopatias , Cardiomiopatia Dilatada , Lactente , Camundongos , Animais , Humanos , Criança , Feminino , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/genética , Volume Sistólico , Proteínas Adaptadoras de Transdução de Sinal/genética , Proteínas com Domínio LIM/genética , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA